The application analyses for primary spectrum pyrometer. (English) Zbl 1206.80007
Summary: In the applications of primary spectrum pyrometry, based on the dynamic range and the minimum sensibility of the sensor, the application issues, such as the measurement range and the measurement partition, were investigated through theoretical analyses. For a developed primary spectrum pyrometer, the theoretical predictions of measurement range and the distributions of measurement partition were presented through numerical simulations. And the measurement experiments of high-temperature blackbody and standard temperature lamp were processed to further verify the above theoretical analyses and numerical results. Therefore the research in the paper provides the helpful supports for the applications of primary spectrum pyrometer and other radiation pyrometers.
MSC:
80A20 Heat and mass transfer, heat flow (MSC2010)
78A40 Waves and radiation in optics and electromagnetic theory
PDF BibTeX XML Cite
Full Text: DOI
References:
[1] Modest M F. Radiative Heat Transfer. New York: McGraw-Hill Book Company, 1993. 9–11, 27–28
[2] Coates P B. Multi-wavelength pyrometry. Metrologia, 1981, 17: 103–109 · doi:10.1088/0026-1394/17/3/006
[3] Sun X G, Dai J M, Cong D C, et al. Theoretical study of multi-wavelength radiation thermometry-autosearch for emissivity expression general. Int J Infrared Millim Waves, 1998, 17(3): 221–225
[4] Zhang H, Pan J L, Liao B J, et al. Influence of variables on the system of real-time measurement of temperature field with ICCD as sensor. Sci China Ser E-Technol Sci, 1999, 42(1): 21–27 · doi:10.1007/BF02917054
[5] Bhattacharjee S, King M, Cobb W, et al. Approximate two-color emission pyrometry. J Heat Transfer Trans ASME, 2000, 122(1): 15–20 · doi:10.1115/1.521431
[6] Ng D, Fralick G. Use of a multi-wavelength pyrometer in several elevated temperature aerospace applications. Rev Sci Instrum, 2001, 72(2): 1522–1530 · doi:10.1063/1.1340558
[7] Jenkins T P, Hanson R K. Soot pyrometry using modulated absorption/emission. Combust Flame, 2001, 126(3): 1669–1679 · doi:10.1016/S0010-2180(01)00278-4
[8] Sabel T, Unterberger S, Hein K R G. Application of quotient pyrometry to industrial pulverised coal combustion. Exp Therm Fluid Sci, 2002, 26(2–4): 283–289 · doi:10.1016/S0894-1777(02)00138-3
[9] Cheng X F, Fu T R, Wang A Q. Measurement of temperature using radiation approach: A theoretical analysis. Spectrose Spectra Anal, 2002, 22(2): 180–182
[10] Lu G, Yan Y, Riley G, et al. Concurrent measurement of temperature and soot concentration of pulverized coal flames. IEEE Trans Instrum Meas, 2002, 51(5): 990–995 · doi:10.1109/TIM.2002.807804
[11] Cheng X F, Fu T R, Wang A Q. Tri-waveband method for temperature measurement of the object with monotonic emissivity property. Spectrosc Spectra Anal, 2003, 23(4): 641–646
[12] Mazikowski A, Chrzanowski A. Non-contact multiband method for emissivity measurement. Infrared Phys Technol, 2003, 44(2): 91–99 · doi:10.1016/S1350-4495(02)00182-2
[13] Saunders P, White D R. Physical basis of interpolation equations for radiation thermometry. Metrologia, 2003, 40(4): 195–203 · doi:10.1088/0026-1394/40/4/309
[14] Fu T R, Cheng X F, Fan X L, The principle of primary spectrum pyrometry. Sci China Ser G-Phys Mech Astron, 2005, 48(2): 142–149 · doi:10.1360/04yw0069
[15] Fu T R, Cheng X F, Wu B. Study of correlated color temperature and thermodynamic temperature of a radiating source. Metrologia, 2004, 41(6): 439–443 · doi:10.1088/0026-1394/41/6/012
[16] Fu T R, Cheng X F, Fan X L, et al. The analysis of optimization criteria for multi-band pyrometry. Metrologia, 2004, 41(4): 305–313 · doi:10.1088/0026-1394/41/4/012
[17] Fu T R, Cheng X F, Zhong M H, et al. The theoretical prediction analyses of the measurement range for multi-band pyrometry. Meas Sci Technol, 2006, 17: 2751–2756 · doi:10.1088/0957-0233/17/10/029
[18] Fu T R, Cheng X F, Zhong M H, et al. The temperature field partition for primary spectrum pyrometry. Spectrosc Spectra Anal, 2006, 26(12): 2166–2168
[19] Fu T R, Cheng X F, Shi C L, et al. The set-up of a vision pyrometer. Meas Sci Technol, 2006, 17: 659–665 · doi:10.1088/0957-0233/17/4/008
This reference list is based on information provided by the publisher or from digital mathematics libraries. Its items are heuristically matched to zbMATH identifiers and may contain data conversion errors. It attempts to reflect the references listed in the original paper as accurately as possible without claiming the completeness or perfect precision of the matching.