Clamped-free double-walled carbon nanotube-based mass sensor. (English) Zbl 1381.74102
Summary: In this study, we investigate the vibrations of the cantilever double-walled carbon nanotube (DWCNT) with attached bacterium on the tip in the view of developing the sensor. This sensor will be able to help to identify the bacterium or virus that may be attached to the DWCNT. Four cases are considered; these are light or heavy bacteria attached to either inner or outer nanotube. The problem is solved by the finite difference method.

MSC:
74H45 Vibrations in dynamical problems in solid mechanics
74S20 Finite difference methods applied to problems in solid mechanics
PDF BibTeX XML Cite
Full Text: DOI
References:
[1] Iijima S.: Helical microtubes of graphite carbon. Nature 354, 56–58 (1991)
[2] Kiani, K.: Application of nonlocal beam models to double-walled carbon nanotubes under a moving nanoparticle. Part I: theoretical formulations. Acta Mech. (2010). doi: 10.1007/s00707-010-0362-1 · Zbl 1398.74145
[3] Ece M.C., Aydogdu M.: Nonlocal elasticity effect on vibration of in-plane loaded double-walled carbon nano-tubes. Acta Mech. 190, 185–195 (2007) · Zbl 1117.74022
[4] Wu D.H., Chien W.T., Chen C.S., Chen H.H.: Resonant frequency analysis of fixed-free single-walled carbon nanotube-based mass sensor. Sens. Actuat. 126, 117–121 (2006)
[5] Gupta A., Akin D., Bashir R.: Single virus particle mass detection using microresonators with nanoscale thickness. Appl. Phys. Lett. 84, 1976–1978 (2004)
[6] Mateiu R., Davis Zachary J., Madsen Dorte N., Molhave K., Boggild P., Rassmusen A.M., Brorson M., Jacobsen and Claus J.H., Boisen A.: An approach to a multi-walled carbon nanotube based mass sensor. Microelectron. Eng. 73, 670–674 (2004)
[7] Mateiu R., Kuhle A., Marie R., Boisen A.: Building a multi-walled carbon nanotube-based mass sensor with the atomic force microscope. Ultramicroscopy 105, 233–237 (2005)
[8] Braun T., Ghatkesar M.K., Backmann N., Grange W., Boulanger P., Letellier L., Lang H.-P., Bietsch A., Gerber C., Hegner C.: Quantitative time-resolved measurement of membrane protein-ligand interactions using microcantilever array sensors. Nat. Nanotechonol. 4, 179–185 (2009)
[9] Elishakoff I., Pentaras D.: Some modern problems in structural engineering dynamics. Shock Vibr. 37, 331–348 (2010)
[10] Fraenkel-Conrat H.: The Viruses, Catalogue, Characterization, and Classification. Plenum Press, New York, London (1985)
[11] Gunsalus I.C., Stanier R.I.: The bacteria, a treatise on structure and function. Academic Press, New York, London (1960)
[12] Laura P.A.A., Pombo J., Susemihl E.A.: A note on the vibration of a clamped-free beam with a mass at the free end. J. Sound Vibr. 37, 161–168 (1974)
[13] Laura P.A.A.: Comments on Vibration of a cantilever beam with a base excitation and tip mass. J. Sound Vibr. 88, 569 (1983)
[14] To C.W.S.: Vibration of a cantilever beam with a base excitation and tip mass. J. Sound Vibr. 83, 445–460 (1982)
[15] To C.W.S.: Author’s reply. J. Sound Vibr. 88, 570–571 (1983)
[16] Soedel W.: On the philosophy of absolute truth in structural vibrations. J. Sound Vibr. 93, 465–468 (1984)
[17] Maltbaek J.C.: The influence of a concentrated mass on the free vibrations of a uniform beam. Int. J. Mech. Sci. 3, 219–228 (1960)
[18] Jacquot R.G.: Further comments on vibration of a cantilever beam with a base excitation and tip mass. J. Sound Vibr. 93, 312–313 (1984)
[19] Gottlieb H.P.W.: Equivalence of a mode formula of Laura et al. and To. J. Sound Vibr. 95, 557–558 (1984)
[20] Pearlstein A.J.: On the equivalence of two sets of mode shapes in a cantilever beam problem. J. Sound Vibr. 95, 559–560 (1984)
[21] Salvadori M.G.: Numerical computation of buckling loads by finite difference. ASCE 116, 590–624 (1951)
This reference list is based on information provided by the publisher or from digital mathematics libraries. Its items are heuristically matched to zbMATH identifiers and may contain data conversion errors. It attempts to reflect the references listed in the original paper as accurately as possible without claiming the completeness or perfect precision of the matching.