A numerical evaluation of eddy currents distribution in the human knee with metallic implant. (English) Zbl 1358.78044

Summary: Purpose{ } - The purpose of this paper is to use numerical methods and modelling to estimate the effect of a passive, metallic (conducting) implant on eddy currents distribution in a human knee model. There exists a concern among wearers of such implants that they alter electromagnetic field (eddy currents) significantly and there is a need for standardization of that problem.{ }Design/methodology/approach{ } - The numerical model of a human knee has been built on the base of Visual Human Project and electromagnetic field calculations were carried out using Meep FDTD engine. In total, two scenarios have been considered: the knee model with and without a metallic implant. The knee implant model has been prepared as the knee model with overestimated electrical parameters of bone tissues by titanium metal. Alternating eddy current distribution has then been evaluated for both models using FDTD low frequency algorithm.{ }Findings{ } - The highest values of eddy currents occurred on the interface between skin and muscle tissues when the model without an implant is considered. However, when the bone tissues have been replaced with titanium metal, the highest values have occurred in the implant (about 100 times higher than the previous one). This means that an implant can be heated by external electromagnetic fields and that the location of the highest values of eddy currents can be shifted to the proximity of the implant. Moreover, one should realize that in this model the implant is like a knee bone with all anatomical details. It has emerged from this that the implant’s shape and size are essential when evaluating its effect on eddy currents distribution.{ }Practical implications{ } - The interaction of electromagnetic field with implants should be generally further investigated, at least for the presumable worst cases. Such investigation has already been done by some researches but they have been devoted to radio frequencies. The authors believe that the presented research will be helpful in the standardization process, when talking about low frequency electromagnetic field.{ }Originality/value{ } - The presented methodology can be used in the development of computer aid diagnosis systems. Overestimation of electrical parameters of some parts of the model allows us to predict the distribution of electromagnetic field in the model under investigation very quickly. The results presented in the paper can be used during the standardization process.

MSC:

78A70 Biological applications of optics and electromagnetic theory
92C50 Medical applications (general)

Software:

MEEP
PDFBibTeX XMLCite
Full Text: DOI

References:

[1] Berenger, J. (1994), ”A perfectly matched layer for the absorption of electromagnetic waves”, Journal of Computational Physics, Vol. 114, pp. 185-200. , · Zbl 0814.65129 · doi:10.1108/03321641211248147
[2] Gabriel, C., Gabriel, S. and Corthout, E. (1996), ”The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues”, Physics in Medicine and Biology, Vol. 41, pp. 2271-94. , · Zbl 1358.78044 · doi:10.1108/03321641211248147
[3] ICNIRP (1998), ”Guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields (up to 300GHz)”, Health Physics, pp. 494-522. · Zbl 1358.78044 · doi:10.1108/03321641211248147
[4] ICNIRP (2010), ”Guidelines for limiting exposure to time-varying electric and magnetic fields (1Hz-100kHz)”, Health Physics, Vol. 99. · Zbl 1358.78044 · doi:10.1108/03321641211248147
[5] IEEE (2004), IEEE Standard for Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3kHz to 300GHz, Institute of Electrical and Electronics Engineering, New York, NY.
[6] McIntosh, R.L., Anderson, V. and McKenzie, R.J. (2005), ”A numerical evaluation of SAR distribution and temperature changes around a metallic plate in the head of a RF exposured worker”, Bioelectromagnetics, Vol. 26 No. 5, pp. 377-88. , · Zbl 1358.78044 · doi:10.1108/03321641211248147
[7] Miaskowski, A. and Krawczyk, A. (2007), ”Finite difference time domain method for high resolution modeling of low frequency electric induction in humans”, Electrical Review, No. 11, pp. 225-7.
[8] Oskooi, A.F., Roundy, D., Ibanescu, M., Bermel, P., Joannopoulos, J.D. and Johnson, S.G. (2010), ”MEEP: a flexible free-software package for electromagnetic simulations by the FDTD method”, Computer Physics Communications, Vol. 181, pp. 687-702. , · Zbl 1205.78003 · doi:10.1108/03321641211248147
[9] Virtanen, H., Keshvari, J. and Lappalainen, R. (2006), ”Interaction of radio frequency electromagnetic fields and passive metallic implants - a brief review”, Electromagnetics, Vol. 27, pp. 431-9.
[10] Virtanen, H., Keshvari, J. and Lappalainen, R. (2007), ”The effect of authentic metallic implants on the SAR distribution of the head exposed to 900, 1800 and 2450MHz dipole near field”, Phys. Med. Biol., Vol. 52 No. 5, pp. 1221-36. , · Zbl 1358.78044 · doi:10.1108/03321641211248147
This reference list is based on information provided by the publisher or from digital mathematics libraries. Its items are heuristically matched to zbMATH identifiers and may contain data conversion errors. In some cases that data have been complemented/enhanced by data from zbMATH Open. This attempts to reflect the references listed in the original paper as accurately as possible without claiming completeness or a perfect matching.