Optimising lung imaging for cancer radiation therapy. (English) Zbl 1431.90182

Summary: Effective radiotherapy is dependent on being able to (i) visualise the tumour clearly, and (ii) deliver the correct dose to the cancerous tissue, whilst sparing the healthy tissue as much as possible. In the presence of tumour motion, both of these tasks become increasingly difficult to perform accurately. This increases the likelihood of an incorrect dose being delivered to cancerous tissue and exposure of healthy tissue to unnecessary radiation. For tumours in the lung and thoracic region subject to respiratory-induced motion, 4D Cone-Beam CT (4D-CBCT) is a novel approach for producing a sequence of 3D images of the patient’s anatomy throughout different phases of the respiratory cycle. However, current implementations involve sub-optimal heuristic approaches to acquire the imaging data required to account for tumour motion. This leads to undersampling of images for particular phases in the respiratory cycle (such as peak inhale and exhale), resulting in noisy or poorly reconstructed 3D images. In this paper, we present a novel Mixed Integer Program (MIP) to optimise the timing and angles for the acquisition of imaging data. The result is greatly enhanced image quality for each image across the respiratory cycle, whilst minimising motion blur. Numerical experiments indicate that our approach universally improves over the conventional acquisition process by 93% and simultaneously reduces unnecessary dose to the patient and can be solved in under a minute.

MSC:

90C90 Applications of mathematical programming
92C55 Biomedical imaging and signal processing

Software:

ConRad; 3D Slicer
PDFBibTeX XMLCite
Full Text: DOI Link

References:

[1] Fu, A.; Ungun, B.; Xing, L.; Boyd, S., A convex optimization approach to radiation treatment planning with dose constraints, Optimization and Engineering, 20, 277-300 (2019) · Zbl 1428.90118
[2] Abdelnour, A. F.; Nehmeh, S. A.; Pan, T.; Humm, J. L.; Vernon, P.; Schöder, H.; Erdi, Y. E., Phase and amplitude binning for 4D-CT imaging, Physics in Medicine and Biology, 52, 12, 3515 (2007)
[3] American Cancer Society, Cancer treatment and survivorship facts and figures 2016-2017 (2016), American Cancer Society: American Cancer Society Atlanta
[4] Boland, N.; Hamacher, H.; Lenzen, F., Minimizing beam-on time in cancer radiation treatment using multileaf collimators, Networks, 43, 226-240 (2004) · Zbl 1044.92030
[5] Chan, T. C.Y.; Bortfeld, T.; Tsitsiklis, J. N., A robust approach to IMRT optimization, Physics in Medicine and Biology, 51, 10, 2567-2583 (2006)
[6] Chen, W.; Unkelbach, J.; Trofimov, A.; Madden, T.; Kooy, H.; Bortfeld, T.; Craft, D., Including robustness in multi-criteria optimization for intensity modulated proton therapy, Physics in Medicine and Biology, 57, 591-608 (2012)
[7] Cooper, B. J.; O’Brien, R. T.; Balik, S.; Hugo, G. G.; Keall, P. J., Respiratory triggered 4D cone-beam computed tomography: A novel method to reduce imaging dose, Medical Physics, 40, 4, 041901 (2013)
[8] Cooper, B. J.; O’Brien, R. T.; Kipritidis, J.; Shieh, C.-C.; Keall, P. J., Quantifying the image quality and dose reduction of respiratory triggered 4D cone-beam computed tomography with patient-measured breathing, Physics in Medicine and Biology, 60, 24, 9493 (2015)
[9] Deasy, J.; E, E. L.; Bortfeld, T.; Langer, M.; Zakarian, K.; Alaly, J.; Rardin, R., A collaboratory for radiation therapy treatment planning optimization research, Annals of Operations Research, 148, 55-63 (2006) · Zbl 1104.92031
[10] 091909 (14pg.)
[11] Fedorov, A.; Beichel, R.; Kalpathy-Cramer, J.; Finet, J.; Fillion-Robin, J.-C.; Pujol, S.; Kikinis, R., 3d slicer as an image computing platform for the quantitative imaging network., Magnetic Resonance Imaging, 30, 9, 1323-1341 (2012)
[12] Feldkamp, L.; Davis, L.; Kress, J., Practical cone-beam algorithm, Journal of the Optical Society of America, 1, 6, 612-619 (1984)
[13] Available from: http://globocan.iarc.fr, accessed on 11/07/2017.
[14] Fredriksson, A. (2013). Robust optimization of radiation therapy accounting for geometric uncertainty (Ph.D. dissertation).
[15] George, R.; Chung, T.; Vedam, S.; Ramakrishnan, V.; Mohan, R.; Weiss, E.; Keall, P., Audio-visual biofeedback for respiratory-gated radiotherapy: impact of audio instruction and audio-visual biofeedback on respiratory-gated radiotherapy., International Journal of Radiation: Oncology - Biology - Physics, 65, 3, 924-933 (2006)
[16] Keall, P. J.; Mageras, G.; Balter, J.; Emery, R.; Forster, K.; Jiang, S.; Yorke, E., The management of respiratory motion in radiation oncology report of AAPM task group 76, Medical Physics, 33, 10, 3874-3900 (2006)
[17] Lee, E. K.; Fox, T.; Crocker, I., Integer programming applied to intensity-modulated radiation therapy treatment planning, Annals of Operations Research, 119, 1, 165-181 (2003) · Zbl 1046.90050
[18] Leng, S.; Tang, J.; Zambelli, J.; Nett, B.; Tolankanahalli, R.; Chen, G.-H., High temporal resolution and streak-free, Physics in Medicine and Biology, 53, 5653-5673 (2008)
[19] Lodwick, W. A.; McCourt, S.; Newman, F.; Humphries, S., Computational radiology and imaging. the ima volumes in mathematics and its applications, (vol.110 (1999), Springer: Springer New York, NY
[20] O’Brien, R.; Cooper, B. J.; Keall, P. J., Optimizing 4D cone beam computed tomography acquisition by varying the gantry velocity and projection time interval, Physics in Medicine and Biology, 58, 6, 1705 (2013)
[21] O’Brien, R.; Stankovic, U.; Sonke, J.; Keall, P., Reducing 4DCBCT imaging time and dose: the first implementation of variable gantry speed 4DCBCT on a linear accelerator, Physics in Medicine and Biology, 62, 11, 4300-4317 (2017)
[22] O’Brien, R. T.; Cooper, B. J.; Kipritidis, J.; Shieh, C.-C.; Keall, P. J., Respiratory motion guided four dimensional cone beam computed tomography: encompassing irregular breathing, Physics in Medicine and Biology, 59, 3, 579 (2014)
[23] O’Brien, R. T.; Cooper, B. J.; Shieh, C.-C.; Stankovic, U.; Keall, P. J.; Sonke, J.-J., The first implementation of respiratory triggered 4DCBCT on a linear accelerator, Physics in Medicine and Biology, 61, 9, 3488 (2016)
[24] O’Brien, R. T.; Kipritidis, J.; Shieh, C.-C.; Keall, P. J., Optimizing 4DCBCT projection allocation to respiratory bins, Physics in Medicine and Biology, 59, 19, 5631 (2014)
[25] Romeihn, H. E.; Ahuja, R. K.; Dempsey, J. F., A new linear programming approach to radiation therapy treatment planning problems, Operations Research, 54, 201-216 (2006) · Zbl 1167.90587
[26] Santoso, A. P.; Song, K. H.; Qin, Y.; Gardner, S. J.; Liu, C.; Chetty, I. J.; Wen, N., Evaluation of gantry speed on image quality and imaging dose for 4D cone-beam CT acquisition, Radiation Oncology, 11, 98 (2016)
[27] Segars, W. P.; Mahesh, M.; Beck, T. J.; Frey, E. C.; Tsui, B. M.W., Realistic ct simulation using the 4D XCAT phantom, Medical Physics, 35, 8, 3800-3808 (2008)
[28] 041912-1-041912-18
[29] Shieh, C.-C.; Kipritidis, J.; O’Brien, R. T.; Cooper, B. J.; Kuncic, Z.; Keall, P. J., Improving thoracic four-dimensional cone-beam CT reconstruction with anatomical-adaptive image regularization (AAIR), Physics in Medicine and Biology, 60, 2, 841 (2015)
[30] Sonke, J.-J.; Zijp, L.; Remeijer, P.; van Herk, M., Respiratory correlated cone beam CT, Medical Physics, 32, 4, 1176-1186 (2005)
[31] Wang, Z.; Bovik, l. C.; Sheikh, H. R.; Simoncelli, E. P., Image quality assessment: From error visibility to structural similarity, IEEE Transactions on Image Processing, 13, 4 (2004)
This reference list is based on information provided by the publisher or from digital mathematics libraries. Its items are heuristically matched to zbMATH identifiers and may contain data conversion errors. In some cases that data have been complemented/enhanced by data from zbMATH Open. This attempts to reflect the references listed in the original paper as accurately as possible without claiming completeness or a perfect matching.